Advanced Thermal Property Measurement Platform: MP-1
The MP-1 is designed to test the absolute thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity of solids, liquids, pastes and powders with the powerful combination of multiple methods.
- Transient Plane Source (TPS): ISO 22007-2, ISO 22007-7, GB/T 32064 (solids)
- Transient Hot Wire (THW): ASTM D7896 (liquids)
- Modified Transient Plane Source (MTPS): ISO 22007-7:2023
- Transient Line Source (TLS): ASTM D5334-22a, ASTM D5930
- Transient Hot Strip (THS)
The powerful combination of Transient Plane Source (TPS), Transient Hot Wire (THW), Transient Line Source (TLS) and Transient Hot Strip (THS) gives the MP-1 a unique and versatile selection of testing methods for your sample type. The TPS and THW methods are widely used for accurate measurement of absolute thermal conductivity, thermal diffusivity, specific heat and thermal effusivity. This versatility is greatly expanded with the addition of our proprietary Temperature Platform (TP) which is appreciated by academic and commercial users alike.
MP-1 Methods:

Transient Plane Source (TPS) Sensor

Transient Hot Wire (THW) Sensor

Transient Line Source (TLS) Sensor

Transient Hot Strip (THS) Sensor
Specifications
| Methods | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Materials | Solids, pastes, and powders | Liquids and PCMs | Solids, pastes, and powders | Solid rectangles |
Soil, pastes, and polymers |
| Testing Modules |
3-D: Bulk, Anisotropic, Slab Anisotropic, Slab, Finite, Thin-Film 1-D: Standard, 1-D Slab, TR Thin-Films, TR Contact Resistance General: Specific Heat |
Bulk |
3-D: Bulk, Anisotropic, Slab Anisotropic, Slab | 1-D: Standard, 1-D Slab |
Bulk, Anisotropic, Slab | Bulk |
| Thermal conductivity (W/m•K) | 0.005 to 2000 | 0.01 to 2 | 0.03 to 500 | 0.01 to 2 | |
| Thermal diffusivity (mm²/sec) | 0.01 to 1200 | Up to 0.5 | 0.01 to 300 | Up to 0.5 | |
| Specific heat (J/kg-K) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | |
| Thermal effusivity (W√s/m²K) | 5 to 60000 | N/A | 20 to 40000 | N/A | |
| Test time (seconds) | 0.25 to 2560 | 1 | 0.25 to 2560 | 0.25 to 2560 | 180 |
| Accuracy (Thermal conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature range (°C)** |
0 to 300 -160 | -45 to 300 up to 750 / 1000 |
10 to 200 -40 to 200 -160 | -40 | 0 to 300 |
0 to 100 | -50 to 200 | 75 to 300 | -40 to 100 |
| Standard |
ISO 22007-2:2022, ISO 22007-7:2023, GB/T 32064-2015 |
ASTM D7896-19 | ISO 22007-7:2023 |
ASTM D5334-22a, ASTM D5930-17, IEEE 442-2017 |
|
|
* Based on testing module used. ** For temperature, external control required. |